SC30 (Single Channel)

Description

Can be used as a two-hand control in conjunction with an approved evaluation unit.

  • Ø 50 mm sensing area
  • Installation via Ø 22.5 mm mounting hole
  • Compatible with Siemens evaluation units 3SK1 Advanced, 3RK3 MSS, Simatic F-CPU
  • TÜV SÜD tested (EN ISO 13849-1, EN ISO 13851)


APPLICATION: PUNCHING | PRESSES

  • Optical feedback
    green LED (ready for operation)
    yellow LED (switch)
  • Compatibility to safety relays
    3SK1 Advanced
    3RK3 MSS
    Simantic F-CPU
  • 100 % water and oil-proof - IP68
    Sensor is completely sealed in cast resin

Downloads SC30 (Single Channel)

csm_CAPTRON-BA-safeCAP-SC30-thumb_9f13772340
Two-hand control safeCAP SC30 Operating Instructions

+ Download DE
+ Download EN
+ Download PL
csm_safecap-SC30-certificate-ec-type-M6A_c8cf41a09c
EC-Type Examination Certificate safeCAP SC30 No. M6A 028949

safeCAP SC30

+ Download DE
+ Download EN
csm_safeCAP30_einkanalig-DS-V1.0_en_f3f92cd4fe
safeCAP30 single channel

+ Download DE
+ Download EN
csm_CAPTRON-thumb-Catalog-safeCAP_92c8eca291
Two-hand control safeCAP product catalog

Two-hand control safeCAP

+ Download DE
+ Download EN
+ Download CN

Product Images

CAPTRON-Two-hand-control-safeCAP-SC30
CAPTRON-Two-hand-control-safeCAP-SC30_02

Technical Drawings

CAPTRON-safeCAP-SC30-single-channel_drawing04
CAPTRON-safeCAP-SC30-single-channel_drawing03
CAPTRON-safeCAP-SC30-single-channel_drawing02
CAPTRON-safeCAP-SC30-single-channel_drawing01

Application Images

CAPTRON-Two-hand-control-safeCAP-SC30_application1

Housing colors

  • RAL9017-VerkehrsschwarzHousing traffic black (RAL 9017)

Features

  • staticFunction: Static (permanent signal)
  • relSwitching output: PhotoMOS-Relay NO

Specifications

Supply voltage 24V DC (19,2...28,8 V)
Output PhotoMOS-Relais, electronic
Operating temperature -25°C...+75°C
IP protection level Front IP68
Back side IP67
Load current Max. 100 mA
Current consumption Max. 20mA
Switch-off -delay Max. 50 ms
Switch-on-delay Max. 30 ms
Rated insulation voltage 32 V
Optical feedback LED yellow
LED green
Connection M12
Wire count 5-pole
6-pole
Performance Level Ple*
MTTFd 100 Jahre
PFHd 2,47 10-10 /h
Category CAT 4*
DC 0 (99% mit Relais)
TM 20 years
Note* Values are achieved in conjunction with an appropriately approved safety relay for two-hand controls

Suitable Accessories

CAPTRON-two-hand-safety-control-safeCAP-SC3-3SK1

Safety relay 3SK1

For safety applications in conjunction with SC30 (Single Channel)

  • SIRIUS safety switching devices 3SK1
  • For safety applications in conjunction with SC30 (Single Channel)
  • Highest requirements according to IEC 61508/ IEC 62061 (SIL 3) as well as EN ISO 13849-1 (PL e)
     

APPLICATION: PUNCHING | PRESSES

CAPTRON-Accessoires-SCP-6-Protector

SCP-6 Protector

Protector for profile mounting of safeCAP SC30

  • Protector made of transparent polycarbonate
  • Protection to avoid bypassing the two handed operation
     

APPLICATION: PUNCHING | PRESSES

CAPTRON-Accessoires-Mounting-Support-Connection-Cable-M12

Cable M12

M12 cable for sensor connection

  • Straight or angled connector
  • Different lengths are available
  • Different numbers of cores are available
  • Screw mounting
     

APPLICATION: TRAFFIC & TRANSPORT | INDUSTRIAL AUTOMATION